EPOS 3/3 40KL
- Capacity: 40000VA/40000W
- Power Factor (PF): 1
- Battery Option: No internal battery
- Wave Form: Sine wave
- Built-in MBS: Yes
- Dual Input: Yes
- EPO: Yes
- Parallel Option: Yes
- Intelligent Slot: SNMP, AS400, RS485-Modbus
- Network Ports: USB, RS-232
- Box contents: UPS, user manual, software CD, USB cable
External Battery Pack Options
EPOS 3/3 Series
描述

3 Phase Tower UPS Solutions FSP EPOS 3P/3P, 3P/1P Online UPS series integrates true double-conversion design, DSP technology, and active input power factor correction design to ensure output power quality and performance at all times. N+X redundancy function available reduces power failure or lost rick. Besides, an easy-configurable program via LCD panel enhances the flexibility to meet the ever-increasing power demand of IT and networked environment.
- True double conversion
- DSP technology for high reliability
- Output power factor 1
- Active power factor correction in all phases
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy saving
- Emergency power off function (EPO)
- Optional parallel operation with common battery
- Smart battery charger design to optimize battery performance
- Maintenance bypass available
- Adjustable battery design
EPOS 3/3 Model | 30KL | 40KL | 60KL | 80KL |
Part Number | PPF30L0201 | PPF36L0403 | PPF54L0203 | PPF80L0302 |
Runtime
Run-Time Table per Loading
Minutes (EPOS 3/3 40KL + BB +-240/18Ah)
Minutes (EPOS 3/3 40KL + 2* BB +-240/18Ah)
Specifications
UPS Specifications:
EPOS 3/3 Model | 10K(L) | 20K(L) | 30KL | 40KL | 60KL | 80KL | |
Capacity | 10KVA/10KW | 20KVA/20KW | 30KVA/30KW | 40KVA/40KW | 60KVA/60KW | 80KVA/80KW | |
Input | |||||||
Voltage
Range |
Low line loss | 110 VAC(Ph-N) ± 3 % at 50% Load; 176 VAC(Ph-N) ± 3 % at 100% Load | |||||
Low line Comeback | Low Line Loss Voltage + 10V | ||||||
High line loss | 300 VAC(L-N) ± 3 % at 50% Load; 276 VAC(L-N) ± 3 % at 100% Load | ||||||
High line Comeback | High Line Loss Voltage – 10V | ||||||
Frequency Range | 46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system |
||||||
Phase | 3 Phase with Neutral | ||||||
Power Factor | ≧ 0.99 at 100% Load | ||||||
Output | |||||||
Phase | 3 Phase with Neutral | ||||||
Output voltage | 360/380/400/415VAC (Ph-Ph) | ||||||
208*/220/230/240VAC (Ph-N) > EPOS 3P/1P series | |||||||
AC Voltage Regulation | ± 1% | ||||||
Frequency Range (Synchronized Range) |
46Hz ~ 54 Hz @ 50Hz system; 56Hz ~ 64 Hz @ 60Hz system |
||||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | ||||||
Overload | AC Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately | |||||
Batt. Mode | 100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately | ||||||
Current Crest Ratio | 3:1 max | ||||||
Harmonic Distortion | ≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load | ||||||
Transfer Time | Line-Batt. | 0 ms | |||||
Inverter-Bypass | 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass) | ||||||
Inverter-ECO | <10 ms | ||||||
Efficiency | |||||||
AC Mode | 95.5% | ||||||
Batt. Mode | 94.5% | ||||||
Battery | |||||||
Standard
Model |
Type | 12V/9Ah | 12V/10Ah | N/A, currently no standard option | |||
Numbers | (10+10)pcs | (16+16)pcs | |||||
Recharge Time | 9 hours recover to 90% capacity | ||||||
Charging Current | 2.0 A ± 10% (Recommended) 1.0~12.0A (Adjustable) |
||||||
Charging Voltage | +/-136.5 VDC ± 10% |
+/-218 VDC ± 10% | |||||
Long-run Model | Type | Depending on applications | |||||
Numbers | (10+10)pcs | (16+16) ~ (20+20) pcs (Adjustable) | |||||
Charging Current | 1.0~12.0A ± 10% (Adjustable) | 2.0~24.0A ± 10% (Adjustable) | |||||
Charging Voltage | +/-136.5 VDC ± 10% |
+/- 13.65 VDC * N ± 1% (N = 16~20) | |||||
Physical | |||||||
Standard
Model |
Dimension, D X W X H (mm) | 630 x 250 x 826 | N/A, currently no standard option | ||||
Net Weight (kgs) | 126 | 141 | |||||
Long-run Model | Dimension, D X W X H (mm) | 630 x 250 x 826 | 815 x 300 x 1000 | 790 x 360 x 1010 | |||
Net Weight (kgs) | 30 | 45 | 65 | 71 | 112 | 117 | |
Environment | |||||||
Operation Temperature | 0 ~ 40°C (the battery life will down when > 25°C) | ||||||
Operation Humidity | <95 % and non-condensing | ||||||
Operation Altitude* | <1000m** | ||||||
Acoustic Noise Level | Less than 55dB @ 1 Meter |
Less than 58dB @ 1 Meter |
Less than 65dB @ 1 Meter |
Less than 70dB @ 1 Meter |
Less than 70dB @ 1 Meter |
Less than 75dB @ 1 Meter |
|
Management | |||||||
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC | ||||||
Optional SNMP | Power management from SNMP manager and web browser |
*If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated 1% per 100m.
**Product specifications are subject to change without further notice.
Accessories
Battery Pack
Network Management