EPOS 3/3 30KL

  • Capacity: 30000VA/30000W
  • Power Factor (PF): 1
  • Battery Option: No internal battery
  • Wave Form: Sine wave
  • Built-in MBS: Yes
  • Dual Input: Yes
  • EPO: Yes
  • Parallel Option: Yes
  • Intelligent Slot: SNMP, AS400, RS485-Modbus
  • Network Ports: USB, RS-232
  • Box contents: UPS, user manual, software CD, USB cable

External Battery Pack Options

EPOS 3/3 Series

描述

Epos Series_2701

3 Phase Tower UPS Solutions FSP EPOS 3P/3P, 3P/1P Online UPS series integrates true double-conversion design, DSP technology, and active input power factor correction design to ensure output power quality and performance at all times. N+X redundancy function available reduces power failure or lost rick. Besides, an easy-configurable program via LCD panel enhances the flexibility to meet the ever-increasing power demand of IT and networked environment.

  • True double conversion
  • DSP technology for high reliability
  • Output power factor 1
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Optional parallel operation with common battery
  • Smart battery charger design to optimize battery performance
  • Maintenance bypass available
  • Adjustable battery design
EPOS 3/3 Model 30KL 40KL 60KL 80KL
Part Number PPF30L0201 PPF36L0403 PPF54L0203 PPF80L0302

Runtime

Run-Time Table per Loading

Minutes (EPOS 3/3 30KL + BB +-240/18Ah)

Chart by Visualizer

Minutes (EPOS 3/3 30KL + 2* BB +-240/18Ah) 

Chart by Visualizer

Specifications

UPS Specifications:

EPOS 3/3 Model 10K(L) 20K(L) 30KL 40KL 60KL 80KL
Capacity 10KVA/10KW  20KVA/20KW  30KVA/30KW  40KVA/40KW  60KVA/60KW  80KVA/80KW
Input
Voltage

Range

Low line loss 110 VAC(Ph-N) ± 3 % at 50% Load; 176 VAC(Ph-N) ± 3 % at 100% Load
Low line Comeback Low Line Loss Voltage + 10V
High line loss 300 VAC(L-N) ± 3 % at 50% Load; 276 VAC(L-N) ± 3 % at 100% Load
High line Comeback High Line Loss Voltage – 10V
Frequency Range 46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
Phase 3 Phase with Neutral
Power Factor ≧ 0.99 at 100% Load
Output
Phase 3 Phase with Neutral
Output voltage 360/380/400/415VAC (Ph-Ph)
208*/220/230/240VAC (Ph-N) > EPOS 3P/1P series
AC Voltage Regulation ± 1%
Frequency Range
(Synchronized Range)
46Hz ~ 54 Hz @ 50Hz system;
56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Overload AC Mode 100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
Batt. Mode 100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
Current Crest Ratio 3:1 max
Harmonic Distortion ≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load
Transfer Time Line-Batt. 0 ms
Inverter-Bypass 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
Inverter-ECO <10 ms
Efficiency
AC Mode 95.5%
Batt. Mode 94.5%
Battery
Standard

Model

Type 12V/9Ah 12V/10Ah N/A, currently no standard option
Numbers (10+10)pcs (16+16)pcs
Recharge Time 9 hours recover to 90% capacity
Charging Current 2.0 A ± 10% (Recommended)
1.0~12.0A (Adjustable)
Charging Voltage +/-136.5 VDC
± 10%
+/-218 VDC ± 10%
Long-run Model Type Depending on applications
Numbers (10+10)pcs (16+16) ~ (20+20) pcs (Adjustable)
Charging Current 1.0~12.0A ± 10% (Adjustable) 2.0~24.0A ± 10% (Adjustable)
Charging Voltage +/-136.5 VDC
± 10%
+/- 13.65 VDC * N ± 1% (N = 16~20)
Physical
Standard

Model

Dimension, D X W X H (mm) 630 x 250 x 826 N/A, currently no standard option
Net Weight (kgs) 126 141
Long-run Model Dimension, D X W X H (mm) 630 x 250 x 826 815 x 300 x 1000 790 x 360 x 1010
Net Weight (kgs) 30 45 65 71 112 117
Environment
Operation Temperature 0 ~ 40°C (the battery life will down when > 25°C)
Operation Humidity <95 % and non-condensing
Operation Altitude* <1000m**
Acoustic Noise Level Less than 55dB
@ 1 Meter
Less than 58dB
@ 1 Meter
Less than 65dB
@ 1 Meter
Less than 70dB
@ 1 Meter
Less than 70dB
@ 1 Meter
Less than 75dB
@ 1 Meter
Management
Smart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

*If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated 1% per 100m.

**Product specifications are subject to change without further notice.

Accessories

Battery Pack

Network Management

Support

FSP UPS selector

If you feel hard to identify the differences between our UPSs, try our UPS selector! Input the power capacity and the preferred features to get what you need!

New Project (28)

Project Inquiry

Do you still have any concern about the UPS you selected? Or are you facing unique requests in a complex site environment? You can consult with us!

New Project (24)

Knowledge Center

Not sure about any UPS function, battery, operation or maintenance? Check out our knowledge center. We’ve categorized the knowledge not only by entry or advanced, but also by functions and features!

New Project (33)

Download

Product Technical Files

Software & Certification

Fortron Source GmbH|FSP Group EU branch
FSP Group is one of the global leading power supply manufacturers. Our products include AC DC power supplies, UPS, energy storage systems, battery chargers & more. Learn more about FSP Group.
© 2021 By Fortron Source GmbH (FSP GROUP). All rights reserved
Footer color